Glossary entry (derived from question below)
English term or phrase:
wet contact
German translation:
unter Spannung stehender / stromführender Kontakt
Added to glossary by
AErdmann
Apr 22, 2010 13:02
14 yrs ago
3 viewers *
English term
wet contact
English to German
Tech/Engineering
Electronics / Elect Eng
Switches/contacts
Die Definition zu ***wet contact*** habe ich schon gefunden (s. u.), wie aber wird das auf Deutsch bezeichnet? Vielen Dank!
A dry contact is a contact that does not provide voltage. For instance, the push-to-talk switch of a microphone, which just closes a circuit without providing voltage.
A wet contact is a contact that will provide voltage when closed, like the switch on the wall that activates the 110 VAC outlet to turn a lamp on in a room.
A dry contact is a contact that does not provide voltage. For instance, the push-to-talk switch of a microphone, which just closes a circuit without providing voltage.
A wet contact is a contact that will provide voltage when closed, like the switch on the wall that activates the 110 VAC outlet to turn a lamp on in a room.
Proposed translations
(German)
4 +1 | unter Spannung stehender / stromführender Kontakt | Johannes Gleim |
4 | potentialbehafteter Kontakt | Herbie |
3 | Nasskontakt | Rolf Kern |
Proposed translations
+1
10 hrs
Selected
unter Spannung stehender / stromführender Kontakt
Jumper selectable dry contact/wet contact input signals
:
Each isolated input supports both dry contact and wet contact so that it can easily interface with other devices when no voltage is present in the external circuit.
http://www.sphinxconnect.ch/Advantech/Advantech-PCI-1760U/p1...
Dry Contact:
Logisch 0 = verbunden mit Masse
Logisch 1 = offen
Wet Contact:
Logisch 0 = max. 4 V
Logisch 1 = 10 bis 50 V
http://www.aaeon.ch/produkte/115604/web/spectra/Datenblatt-I...
• “Dry Contact” (Statuskontrolle eines Schließkontaktes):
logisch “0”: Eingang auf Masse geschaltet
logisch “1”: Eingang geöffnet
• “Wet Contact” (Kontrolle einer anliegenden Spannung):
logisch “0”: 0...+ 2 V
logisch “1”:+4...+30 V
http://www.daqdata.de/product_info.php?products_id=43
Eingänge für spannungsgesteuerte (Wet Contact) und zustandsgesteuerte (dry contact) Signale konfigurierbar.
http://www.kolbinger.at/DAQM/pdf/I-7055.pdf
:
Each isolated input supports both dry contact and wet contact so that it can easily interface with other devices when no voltage is present in the external circuit.
http://www.sphinxconnect.ch/Advantech/Advantech-PCI-1760U/p1...
Dry Contact:
Logisch 0 = verbunden mit Masse
Logisch 1 = offen
Wet Contact:
Logisch 0 = max. 4 V
Logisch 1 = 10 bis 50 V
http://www.aaeon.ch/produkte/115604/web/spectra/Datenblatt-I...
• “Dry Contact” (Statuskontrolle eines Schließkontaktes):
logisch “0”: Eingang auf Masse geschaltet
logisch “1”: Eingang geöffnet
• “Wet Contact” (Kontrolle einer anliegenden Spannung):
logisch “0”: 0...+ 2 V
logisch “1”:+4...+30 V
http://www.daqdata.de/product_info.php?products_id=43
Eingänge für spannungsgesteuerte (Wet Contact) und zustandsgesteuerte (dry contact) Signale konfigurierbar.
http://www.kolbinger.at/DAQM/pdf/I-7055.pdf
Peer comment(s):
agree |
Bernd Runge
: spannungsgesteuert - wet wird auch als switched-voltage signal bezeichnet. Es liegt also immer eine Spannung an, anders als beim "An/Aus-Schalter".
7 hrs
|
Danke!
|
4 KudoZ points awarded for this answer.
Comment: "Vielen Dank an alle!"
3 hrs
potentialbehafteter Kontakt
Scheint der geläufigste Gegensatz zum potentialfreien K. zu sein.
Siehe zB: www.omega.de/produkt/p2/adam.html
Siehe zB: www.omega.de/produkt/p2/adam.html
7 hrs
Nasskontakt
Wird zumindest hier verwendet:
http://74.125.77.132/search?q=cache:zB4gwcvMC7QJ:www.perlesy...
http://74.125.77.132/search?q=cache:zB4gwcvMC7QJ:www.perlesy...
Discussion
The UPM includes the following features:
...
MALFUNCTION OUTPUT – The controller has a set of
wet contacts for remote fault indication.
...
Worum geht es hier eigentlich? Wo werden "wet contacts" verwendet? Bitte den Satz zitieren!
Ich habe auch schon mal von wet contact=NC (normally closed) contact gehört. Das wäre dann ein Öffner, der den Stromkreis allerdings unterbricht.